6. INSTALLATION
6.1 Mains voltage
Before you connect the INTELLIGATE to the mains, please make sure that your local voltage matches
the voltage required by the unit! The fuse holder on the female mains connector has 3 triangular markers,
with two of these triangles opposing each other. The INTELLIGATE is set to the operating voltage printed next
to these markers and can be set to another voltage by turning the fuse holder by 180°. CAUTION: This
instruction does not apply to export models exclusively designed, e.g. for 115 V operation!
Please use the enclosed power cord to connect the unit to the mains. The cord complies with all applicable
safety standards.
6.2 Audio connections
The audio inputs and outputs on the BEHRINGER INTELLIGATE are fully balanced. If possible, connect the
unit to other devices in a balanced configuration to allow for maximum interference immunity.
Please ensure that only qualified persons install and operate the INTELLIGATE. During installation
and operation the user must have sufficient electrical contact to earth. Electrostatic charges
might affect the operation of the INTELLIGATE!